background image

4

GENERAL SAFETY WARNINGS

The Operation Manual is an integral part of the product and so must 

be carefully preserved in order to accompany the product; if it is 

lost or damaged another copy can be requested from the Technical 

Assistance Centre.

  The installation of the device and any other repairs or mainte-

nance must be performed by qualified personnel according to 

the law in force, in compliance with the installing regulations 

including any revisions.  

  It is recommended that trained personnel install the device.
  The device must be used according to the manufacturer spe-

cifications. The manufacturer cannot be held contractually or 

otherwise responsible for damage caused to persons, ani-

mals or objects as a result of incorrect installation, repair or 

maintenance or improper usage.

  The product’s safety or automatic regulation devices must not 

be modified unless performed by the manufacturer.

  This device is intended for heating water and therefore must 

be connected to a water distribution network who’s load and 

settings are compatible with the product.

  If water spills, turn off the water supply and advise the quali-

fied personnel at the Technical Assistance Centre.

  If the machine is not used for prolonged periods turn off the 

gas supply. If there is a risk of the water freezing, empty the 

water heater.

  If the machine breaks down or does not function properly, 

deactivate it, do not attempt to perform any repairs. 

  The machine’s maintenance must be performed at least once 

a year: Book a maintenance session with the Technical Assi-

stance Centre ahead of time to save wasting time and money 

afterwards.

The water heater package contains: 

2  

Two knobs to attach to the control panel after installation 

1  

Water filter to insert in the water valve pipe fitting. 

1. TECHNICAL CHARACTERISTICS

1.a  Technical Data

When using the device the following safety rules must be applied:

  Do not use the machine for purposes other than those inten-

ded by the manufacturer.

  Do not block the intake and dissipation grills or the ventilation 

openings in the area where the device is installed with rags, 

paper or any other materials. 

  If a gas leak is detected, do not switch on any electrical de-

vices, telephones or any other objects that could produce a 

spark. Ventilate the area by opening the doors and windows 

and switch off the gas supply.

  Do not place objects on top of the device.

  Do not leave flammable containers or substances in the area 

where the device is installed.

  Do not attempt to repair the machine if it breaks down and/or 

works incorrectly.

  Children or inexperienced persons are prohibited from using 

the device. 

  It is prohibited to open sealed elements.

To maintain the proper functioning of the device:

-  Periodically clean the devices exterior with soapy water, this im-

proves its appearance as well as preserving it from corrosion in 

the long term.

-  Do not use solvents, powders or abrasive sponges.

-  Do not clean the device and/or its parts with flammable materials 

(e.g. petrol, alcohol, diesel etc.).  

    

          

Baxi 11i

Baxi 14i

kW  

kcal/h

kW 

kcal/h

Nominal power usage (Pn)

19,0

16.340

23,7

20.374

Nominal Thermal range (Qn)

21,8

18.748

27,2

23.392

Minimal power usage (Pm)

7,5

6.424

7,5

6.424

Minimal Thermal range (Qm)

9,0

7.740

9,0

7.740

GAS TYPE

METHANE GAS

  LIQUID GAS

METHANE GAS

  LIQUID GAS

G20

 G30

G31

  G20

   G30     

  G31

P.C.I. (15° C 1013 mbar) 

MJ/m3

34,02

116,09

88

34,02

116,09

88

WI      (15° C 1013 mbar)

MJ/m3

45,67

 80,58

70,69

45,67

80,58

70,69

Nominal feed pressure

mbar

20

 28-30

37

20

28-30

37

Consumption

m3/h

2,31

-

-

2,88

-

-

kg/h

-

1,72

1,69

-

2,14

2,11

Burner Pressure   

mbar

12,20

27,50

35,10

13,00

27,00

34,30

Ø pilot flame nozzle

mm 

0,35

0,25

0,35

0,25

Ø main burner nozzle

mm

1,18

0,71

1,18

0,72

nozzles      

N.

11

13

Ø gas connection

1/2”

 1/2”

Maximum flue gas load

g/s

13,20

 12,40

13,00

18,40

17,70

19,00

flue gas temperature

°C

185

180

182

168

163

158

Category

II2H3+

WATER

Baxi 11i

Baxi 14i

Input range   

l /min

select. min.

da 2,5  a 5

select. max  

da 5  a 10,8 

select. min.

da 2,5  a 6,7

select. max  

da 6,7  a 13,6

Water temperature elevation

°C

approximately 50

approximately 25

approximately 50

approximately 25

Minimum pressure 

bar

0,2 

0,2

Nominal pressure 

bar

2

2

Maximum pressure 

bar

10

10

Ø Water connections 

1/2”

1/2”

Ø flue gas release tube

mm

110

130

DIMENSIONS AND WEIGHTS

DEVICE

PACKAGE

DEVICE

PACKAGE

Height

mm

592

655

650

713

Length

mm

314

361

363

410

Depth

mm

245

280

245

280

Weight 

Kg

11,10

13,10

12,60

15,10

Note: relative cold water temperature of 15 °C

Содержание 11i

Страница 1: ...Baxi 11i Baxi 14i INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ......

Страница 3: ...d on the product indicates that it conforms to the following European Directives 142 2009 93 68 0694 0694CP4791 INDEX GENERAL SAFETY pag 4 1 TECHNICAL CHARACTERISTICS pag 4 1 a Technical Data pag 4 2 INSTALLATION pag 6 2 a Regulations pag 6 2 b Mounting to wall pag 6 2 c Room ventilation pag 6 2 d Electrical connection to battery pag 6 2 e Gas Connection pag 7 2 f Water connection pag 7 2 g Dispos...

Страница 4: ...terials If a gas leak is detected do not switch on any electrical de vices telephones or any other objects that could produce a spark Ventilate the area by opening the doors and windows and switch off the gas supply Do not place objects on top of the device Do not leave flammable containers or substances in the area where the device is installed Do not attempt to repair the machine if it breaks do...

Страница 5: ...Temperature regulator 8 Gas valve 9 Gas input 10 Gas adjustment screws 11 Electronic devices 12 Battery box 13 Economiser 14 Gas pressure intake 15 Pilot burner 16 Sensor Fig 1 Misure in mm A B Ø C D E F G H 11i 592 110 101 245 314 97 54 25 14i 650 130 101 245 365 117 74 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig 2 ...

Страница 6: ...or fan fireplaces and other simi lar devices at the same time as the water heater The area where the water heater is installed must have a regular flow of air for ventilation Air flow The flow of air must occur by the following means Permanent openings in the wall that lead outdoors Single or collective ventilation ducts The air used for ventilation must be taken directly from an outside location ...

Страница 7: ...iser 20 Gas valve 21 Safety device 22 Gas filter 23 Battery 24 Electrical card 25 Microswitch 26 Sensor Fig 6 2 g Disposal of waste product This B11BS water heater is supplied with a device for releasing flue gas For output of combustion by products refer to the regulations in force including any updates See paragraph 2 a The gas devices with an attachment for a waste gas flue must be connected di...

Страница 8: ...ring taking care with the di rection of the insertion fig 16 and making sure that the drilled spring guide disc is in its correct position fig 15 Remount the diffuser attaching it to the upper hole Remount the pilot flame IV DISABLING THE GAS ADJUSTER Remove the protective cap Regulate the supply calibration screws so that the maximum amount of gas can pass disk completely horizontal After regulat...

Страница 9: ...f the burner automatically switches off the device then awaits another heating request If after 60 seconds it does not switch on the flame detector inter rupts the flow of gas and blocks the device To reuse the device after it has been blocked close the hot water extraction tap and then reopen it to restart the sequence If the main burner accidentally switches off the device will attempt to turn i...

Страница 10: ...broken Test substitute There isn t sufficient water pressure Repair the device to guarantee pressure rotate the selector knob all the way to the right The membrane is broken Substitute The electrode is damaged Substitute The pilot does not switch on when there is a spark Safety device broken Substitute No gas supply Open the gas tap Air in the gas tubes Release gas The burner does not switch off w...

Страница 11: ... G30 G31 28 30 37 mbar Baxi 11i Pn 19 0 kW Qn 21 8 kW Pm 7 5 kW Qm 9 0 kW P H2O max 10 0 bar B11BS Made in IR 1 5 V Pn Nominal power usage Qn Nominal thermal range Pm Minimal power usage Qm Minimal thermal range P H2 O max Maximum water pressure Category Nominal feed pressure Appliance type Voltage ...