3.a  Function

The water heater is used for the production of instant hot water. 

The removal of hot water can be preformed by multiple taps. 

By turning on the relative tap, the main burner switches on heating 

the water that passes.  

These devices with a modifiable flame are particularly suited for 

usage with mechanical mixers and thermostats.

This water heater, in contrast with other water heaters with a fixed 

flame, has a modulation valve to optimise the water heaters opera

-

tion. It allows for the water to be heated using less water pressure 

and gas by modulating the flame according to the amount of water 

used, maintaining the water extracted at a constant temperature.

The water heater uses automatic variation that is “PROPORTIO-

NAL”, able to change the gas consumption (modulating the flame) 

to respond to the amount of water extracted.

This device is equipped with an electronic tool that is powered by 

a 1.5 V battery that automatically switches on the pilot flame and 

then the burner every time that hot water is extracted.

The flame is switched on using a card that ionizes the flame. 

Model 11i

: for the extraction of 2.5 to 5.5 l/m the temperature of 

the water supplied remains at 60°C, (in this case the has valve sup-

plies the burner with the necessary quantity of gas proportional to 

the water supplied), above 5.5 l/m to 11 l/m the water temperature 

varies from 60°C to 40°C.

Model 14i

: for the extraction of 2.5 to 7 l/m the temperature of the 

water supplied remains at 60°C, (in this case the has valve sup-

plies the burner with the necessary quantity of gas proportional to 

the water supplied), above 7 l/m to 14 l/m the water temperature 

varies from 60°C to 40°C

3.b Usage

Ensure that the gas tap and all water taps are switched off 
-  Turn on the Main gas supply tap or that of the gas tank if using 

Liquefied Petroleum Gas (L.P.G.)

-  Open the gas tap, not supplied with the device, placed immedia-

tely before the water heater on the gas input pipe

-  Rotate knob A towards the large flame (ON 

 ), during rotation, 

when the small flame is reached it is necessary to press lightly 

while turning until it reaches its destination.

-  When hot water is requested, the device automatically turns on 

the pilot flame, this lights the main burner.

-  When the hot water request has terminated (turning the water 

tap off) the burner automatically switches off, the device then 

awaits another heating request. 

If after 60 seconds it does not switch on, the flame detector inter

-

rupts the flow of gas and blocks the device.

To reuse the device after it has been blocked, close the hot water 

extraction tap and then reopen it to restart the sequence. 

If the main burner accidentally switches off, the device will attempt 

to turn it on again. 

3. OPERATION

 A

 =  Gas economizer on/off

  

• 

  off position

     minimum gas level

  

      

 maximum gas level

 B

 = Water temperature selector

 

C

 = Viewer water temperature

If within 60 seconds the device does not function it is blocked.

The device is built to function with normal water pressure; in addi-

tion a temperature selector B is also supplied.

Rotate the knob completely to the left to obtain the maximum water 

output or completely to the right for the minimum water output.

The machine is switched off by rotating knob A to the (

 OFF) po-

sition.

When the water heater is not used for long periods close the gas 

supply tap or the LPG gas valve on the tank.

For the best operational results it is recommended to have a quali-

fied technician service the machine at least once a year.

Gas economizer

The device is equipped with a gas economizing device which is 

used to choose the temperature of the water so it may be supplied 

at the temperature necessary while saving gas.

The economizing device is activated by turning the knob A until it 

reaches the picture of the small flame  (MIN 

 ). Using the econo-

mizer limits the amount of heating when the hot water usage is mo-

dest (water supplied is already warm or there is a reduced usage, 

for example in summer).

DANGER OF FREEZING

If there is a possibility that the area where the device is stalled 

could reach below 0°C, the device must be emptied of all water 

contained.

4. MAINTENANCE 

To maintain the machine at maximum efficiency, have qualified per

-

sonnel perform a maintenance check at least once a year. 

Before cleaning or performing maintenance, opening or disassem-

bling the panels, switch off the device and turn off the gas supply.  

Check the main burner and the pilot flame, the ignition electrode, 

the safety valve and that there is no leakage. Check that there 

is nothing  obstructing the passages within the exchanger smoke 

channel. 

To clean the outside of the panels utilize a cloth with soap and 

water. 

Do not use solvents, powders or abrasive sponges. 

Do not clean the device and/or its parts with flammable materials 

(e.g. petrol, alcohol, diesel etc.). 

Fig. 17

A

B

C

Содержание 11i

Страница 1: ...Baxi 11i Baxi 14i INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ......

Страница 3: ...d on the product indicates that it conforms to the following European Directives 142 2009 93 68 0694 0694CP4791 INDEX GENERAL SAFETY pag 4 1 TECHNICAL CHARACTERISTICS pag 4 1 a Technical Data pag 4 2 INSTALLATION pag 6 2 a Regulations pag 6 2 b Mounting to wall pag 6 2 c Room ventilation pag 6 2 d Electrical connection to battery pag 6 2 e Gas Connection pag 7 2 f Water connection pag 7 2 g Dispos...

Страница 4: ...terials If a gas leak is detected do not switch on any electrical de vices telephones or any other objects that could produce a spark Ventilate the area by opening the doors and windows and switch off the gas supply Do not place objects on top of the device Do not leave flammable containers or substances in the area where the device is installed Do not attempt to repair the machine if it breaks do...

Страница 5: ...Temperature regulator 8 Gas valve 9 Gas input 10 Gas adjustment screws 11 Electronic devices 12 Battery box 13 Economiser 14 Gas pressure intake 15 Pilot burner 16 Sensor Fig 1 Misure in mm A B Ø C D E F G H 11i 592 110 101 245 314 97 54 25 14i 650 130 101 245 365 117 74 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig 2 ...

Страница 6: ...or fan fireplaces and other simi lar devices at the same time as the water heater The area where the water heater is installed must have a regular flow of air for ventilation Air flow The flow of air must occur by the following means Permanent openings in the wall that lead outdoors Single or collective ventilation ducts The air used for ventilation must be taken directly from an outside location ...

Страница 7: ...iser 20 Gas valve 21 Safety device 22 Gas filter 23 Battery 24 Electrical card 25 Microswitch 26 Sensor Fig 6 2 g Disposal of waste product This B11BS water heater is supplied with a device for releasing flue gas For output of combustion by products refer to the regulations in force including any updates See paragraph 2 a The gas devices with an attachment for a waste gas flue must be connected di...

Страница 8: ...ring taking care with the di rection of the insertion fig 16 and making sure that the drilled spring guide disc is in its correct position fig 15 Remount the diffuser attaching it to the upper hole Remount the pilot flame IV DISABLING THE GAS ADJUSTER Remove the protective cap Regulate the supply calibration screws so that the maximum amount of gas can pass disk completely horizontal After regulat...

Страница 9: ...f the burner automatically switches off the device then awaits another heating request If after 60 seconds it does not switch on the flame detector inter rupts the flow of gas and blocks the device To reuse the device after it has been blocked close the hot water extraction tap and then reopen it to restart the sequence If the main burner accidentally switches off the device will attempt to turn i...

Страница 10: ...broken Test substitute There isn t sufficient water pressure Repair the device to guarantee pressure rotate the selector knob all the way to the right The membrane is broken Substitute The electrode is damaged Substitute The pilot does not switch on when there is a spark Safety device broken Substitute No gas supply Open the gas tap Air in the gas tubes Release gas The burner does not switch off w...

Страница 11: ... G30 G31 28 30 37 mbar Baxi 11i Pn 19 0 kW Qn 21 8 kW Pm 7 5 kW Qm 9 0 kW P H2O max 10 0 bar B11BS Made in IR 1 5 V Pn Nominal power usage Qn Nominal thermal range Pm Minimal power usage Qm Minimal thermal range P H2 O max Maximum water pressure Category Nominal feed pressure Appliance type Voltage ...

Страница 12: ......

Отзывы: