background image

10

4.a Removing the casing (Fig. 18)

To remove the outer casing follow the steps below: 
-  Remove the selector Knobs (A and B)

-  Remove the screws (C)

-  Shift the casing upwards to free it from the upper and lateral ho-

oks

-  Shift the casing forwards

-  To reinsert the casing, follow the above steps in reverse order

4.b Troubleshooting: problems and solutions

For the best functioning of the water heater, to prolong its lifetime 

and ensure that it is always safe, ensure that it is inspected at least 

once a year by a trained professional. The trained professional is 

to perform the following maintenance operations: 
-  Remove any rust from the burner 
-  Remove any deposit on the glow plug by the electrode 
-  Clean the combustion tank 
-  Check the ignition, switching off and general functionality of the 

device 

-  Check that the gas and water tubes and connections are sealed

Warning: the flowing repair instructions are only to be performed by 

qualified and authorized technicians.

Fig. 18

PROBLEM

CAUSE  

SOLUTIONS

There is no spark

Exhausted battery

- Substitute

Electrical cable of device is disconnected

- Insert

Electrical card is broken

Test, substitute

There isn’t sufficient water pressure

Repair the device to guarantee pressure, 

rotate the selector knob all the way to the 

right

The membrane is broken

- Substitute

The electrode is damaged 

- Substitute

The pilot does not switch on when 

there is a spark

Safety device broken

- Substitute

No gas supply 

Open the gas tap

Air in the gas tubes

Release gas 

The burner does not switch off 

when the water turns off

Grime on the gas shutter

Test, clean

Valve piston or stem is locked in open po-

sition

Disassemble, clean and eventually substi-

tute

Micro lever is locked in open position

- Test

If an LPG supply, check the gas pressure - 

Regulate and if necessary substitute the 

tank pressure regulator 

The exchanger blade becomes 

dirty in a small amount of time

Poor draught or dusty surroundings

-        Check the smoke channel efficiency

Yellow flame

Check the gas type and clean the burner

Excess gas consumption

Check and regulate

There is a smell of gas

Due to the loss of gas in the tubes, check 

the tubes and find the leak

Do not activate electric switches or any 

object that produces sparks in local area

There is a smell of gas

It can be caused by obstruction in the flue 

gas circuit

Check the efficiency of the smoke channel 

and the flue gas conduit

Excess gas consumption

Check and regulate

Содержание 11i

Страница 1: ...Baxi 11i Baxi 14i INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ......

Страница 3: ...d on the product indicates that it conforms to the following European Directives 142 2009 93 68 0694 0694CP4791 INDEX GENERAL SAFETY pag 4 1 TECHNICAL CHARACTERISTICS pag 4 1 a Technical Data pag 4 2 INSTALLATION pag 6 2 a Regulations pag 6 2 b Mounting to wall pag 6 2 c Room ventilation pag 6 2 d Electrical connection to battery pag 6 2 e Gas Connection pag 7 2 f Water connection pag 7 2 g Dispos...

Страница 4: ...terials If a gas leak is detected do not switch on any electrical de vices telephones or any other objects that could produce a spark Ventilate the area by opening the doors and windows and switch off the gas supply Do not place objects on top of the device Do not leave flammable containers or substances in the area where the device is installed Do not attempt to repair the machine if it breaks do...

Страница 5: ...Temperature regulator 8 Gas valve 9 Gas input 10 Gas adjustment screws 11 Electronic devices 12 Battery box 13 Economiser 14 Gas pressure intake 15 Pilot burner 16 Sensor Fig 1 Misure in mm A B Ø C D E F G H 11i 592 110 101 245 314 97 54 25 14i 650 130 101 245 365 117 74 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fig 2 ...

Страница 6: ...or fan fireplaces and other simi lar devices at the same time as the water heater The area where the water heater is installed must have a regular flow of air for ventilation Air flow The flow of air must occur by the following means Permanent openings in the wall that lead outdoors Single or collective ventilation ducts The air used for ventilation must be taken directly from an outside location ...

Страница 7: ...iser 20 Gas valve 21 Safety device 22 Gas filter 23 Battery 24 Electrical card 25 Microswitch 26 Sensor Fig 6 2 g Disposal of waste product This B11BS water heater is supplied with a device for releasing flue gas For output of combustion by products refer to the regulations in force including any updates See paragraph 2 a The gas devices with an attachment for a waste gas flue must be connected di...

Страница 8: ...ring taking care with the di rection of the insertion fig 16 and making sure that the drilled spring guide disc is in its correct position fig 15 Remount the diffuser attaching it to the upper hole Remount the pilot flame IV DISABLING THE GAS ADJUSTER Remove the protective cap Regulate the supply calibration screws so that the maximum amount of gas can pass disk completely horizontal After regulat...

Страница 9: ...f the burner automatically switches off the device then awaits another heating request If after 60 seconds it does not switch on the flame detector inter rupts the flow of gas and blocks the device To reuse the device after it has been blocked close the hot water extraction tap and then reopen it to restart the sequence If the main burner accidentally switches off the device will attempt to turn i...

Страница 10: ...broken Test substitute There isn t sufficient water pressure Repair the device to guarantee pressure rotate the selector knob all the way to the right The membrane is broken Substitute The electrode is damaged Substitute The pilot does not switch on when there is a spark Safety device broken Substitute No gas supply Open the gas tap Air in the gas tubes Release gas The burner does not switch off w...

Страница 11: ... G30 G31 28 30 37 mbar Baxi 11i Pn 19 0 kW Qn 21 8 kW Pm 7 5 kW Qm 9 0 kW P H2O max 10 0 bar B11BS Made in IR 1 5 V Pn Nominal power usage Qn Nominal thermal range Pm Minimal power usage Qm Minimal thermal range P H2 O max Maximum water pressure Category Nominal feed pressure Appliance type Voltage ...