4.5
If the Fireplace opening is greater than the acceptable dimensions given in this
guide, do not use the back of a fire surround or marble to reduce the opening. This may
cause cracking of the surround back or marble
4.6
The appliance must not stand on combustible materials or carpets
.
4.7
The minimum height from the base of the firplace opening to the underside of any
shelf made from wood or other combustible materials is as follows: -
!
For a shelf up to 150mm deep
Minimum height = 860mm.
!
For a shelf deeper than 150mm
860mm + 12.5mm for every 25mm depth over 150mm
(See Graph 1).
4.8
Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by
heat. They may scorch or become discoloured when close to a heating appliance. Please
bear this in mind when installing.
4.9
This appliance must not be installed in any room that contains a bath or shower or
where steam is regularly present.
4.10
An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be
installed unless the fan is permanently disconnected.
Page 12
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2006.
Graph 1. Combustible shelf clearances