Important! This heater must be earthed.
!
The heater is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm² 3 core
cable.
!
The wires in the cable are coloured in accordance with the following code: -
Live =Brown
Neutral = Blue
Earth = Green / Yellow
!
The electric cable must be safely routed from the heater to an electrical socket.
If the electric cable is damaged, to avoid a hazard it must be replaced by a Baxi Fires
Division authorised service agent, or similarly qualified person (See page 12 of this
guide for useful telephone numbers).
All external wiring between the heater and the electrical supply shall comply with
current IEE regulations.
Heater fixing.
All fixings supplied with the heaters have been identified in figure 2.
Additional fixings may be required if fitting the heater to a plasterboard wall that has a
wooden frame behind it. In such cases we recommend the use of heavy duty cavity
fixings.
Page 7
INSTALLER AND OWNER GUIDE
©
Baxi Heating U.K. Limited 2006.
Figure 2. Loose parts identification (Items are not to scale)