background image

DVS Series

Installation and Operating Manual

10

DVS14 AND DVS18 OPERATION

On the front panel of the DVS14 and DVS18 Desktop Video Switchers is a numbered

button corresponding to each camera input, and a button labelled 

Auto

.

AUTO

OK

MENU

1

2

3

4

Input Selection (1-4) /
Menu Control Buttons

Auto

Button

Input Selection (1-4) /
Menu Control Buttons

Auto

Button

Input Selection 
(5-8) Buttons

AUTO

OK

MENU

1

2

3

4

5

6

7

8

Figure 7 - Front Panel Controls on DVS14 (top) and DVS18 (bottom)

Using these buttons, the units can be operated in one of two modes—

Manual

 or 

Auto

.

Manual Mode

To operate the unit in 

Manual

 mode, press the numbered buttons to view the corresponding

camera on the monitor. The LEDs above the buttons indicate which camera is currently

selected.
Pressing the button for a video source that doesn’t have a camera connected to it will

display a ‘

NO VIDEO

’ message until another camera is selected.

Auto Mode

To operate the unit in 

Auto

 mode, press the 

Auto

 button. The monitor will begin to show

images from each active camera in sequence. Any input that had no video signal present

when the unit was powered up will be omitted from the sequence. To add an input to the

sequence, connect it to a video signal and then manually select that input using the relevant

numbered button. When the sequence is restarted, the new input will be included.
When operating in 

Auto 

mode, the unit displays each camera input for a specific period of

time before displaying the image from the next camera and so on. This period of time is

known as the dwell time and it can be adjusted for each camera individually using the on-

screen menu system (see page 16).
To exit 

Auto 

mode, press any of the numbered input selection buttons.

Содержание DVS14

Страница 1: ...DVS Series Desktop Video Switchers Installation and Operating Manual Please read these instructions before installing your equipment...

Страница 2: ...ion and Operating Manual 2 IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this informatio...

Страница 3: ...eclaration of Conformance 4 Unpacking 4 Overview 5 Rear Panel Connections 7 Connecting the Switcher 8 Alarm I O Connector 9 DVS14 and DVS18 Operation 10 DVS24A and DVS28A Operation 11 The On Screen Me...

Страница 4: ...esidential commercial or light industrial EMC environment Refer to Baxall Limited before using the product is medical and or intrinsically safe applications or in an industrial EMC environment This pr...

Страница 5: ...efinable camera titles Aside from these common features DVS Series switchers fall into two groups those with alarm functionality and those without DVS14 and DVS18 The DVS14 can be connected to four ca...

Страница 6: ...uired Sequences can also be run simultaneously on both monitors Both the DVS24A and DVS28Aunits have alarm functionality The alarm inputs are designed so that when an alarm is triggered the main monit...

Страница 7: ...s Video Output Power Connector Power supply cable strain relief point DVS18 Video Inputs Video Outputs Alarm I O Connector Power Connector Power supply cable strain relief point DVS24A Video Inputs Vi...

Страница 8: ...nputs DVS24A or DVS28A connect the Alarms I O Connector 5 Connect the jack plug from the 12V DC power supply into the jack socket marked 12V DC Use the power supply cable strain relief point to preven...

Страница 9: ...GROUND Pin 1 Figure 5 Alarm Input Connections Alarm Outputs An internal relay is provided so that the DVS can be connected to other equipment The behaviour of this relay can be programmed using the m...

Страница 10: ...sing the button for a video source that doesn t have a camera connected to it will display a NO VIDEO message until another camera is selected Auto Mode To operate the unit in Auto mode press the Auto...

Страница 11: ...n t have a camera connected to it will display a NO VIDEO message until another camera is selected The unit can also be used to manually select and display cameras on the spot monitor To do this hold...

Страница 12: ...uto mode press any of the input selection buttons Note The DVS24A and DVS28A are fitted with alarm inputs The operation of the switchers when in alarm condition depends largely on the settings in the...

Страница 13: ...buttons The and buttons are then used to change the selected parameter for that menu item A menu item with no parameters indicates that a sub menu exists To reveal the sub menu highlight the menu item...

Страница 14: ...is also shown so that the source of the images is easily identifiable For more details see page 15 Dwell Select this option to enter the Dwell sub menu This sub menu is used to specify the dwell time...

Страница 15: ...be selected 2 Using the and buttons highlight the character in the camera title that is to be changed 3 Press the OK button The Letter Selection screen is displayed 4 Using the and buttons navigate th...

Страница 16: ...a input and each of these fields indicates a dwell time in seconds To alter the dwell time of an individual camera input use the and buttons to select the required camera input and use the and buttons...

Страница 17: ...put is no longer current When using this option there is no need for an alarm input to be acknowledged and cleared by an operator Ack Acknowledge An alarm input must be cleared by pressing the button...

Страница 18: ...ore the alarm was activated OUTPUT This item is used to specify how the relay contact a set of three pins in the Alarms I O Connector that controls the alarm output works when an alarm input is trigge...

Страница 19: ...ad woodscrews 2 Fit screw A leaving it protruding from the surface by approximately 6 5mm 3 Locate the keyhole shaped slot on the underside of the DVS unit over the head of the screw Slide the DVS unt...

Страница 20: ...m Dwell time is individually adjustable between 1 and 60 seconds on main monitor and globally adjustable between 5 and 60 seconds on second monitor 12 character camera title for each input individuall...

Страница 21: ...1 75 5mm 75 5mm 95mm Max Hole Size 3 8mm Max Hole Size 3 8mm Max Hole Size 3 8mm ORIGINAL SCALE 1 1 It is imperative that the dimensions on the supplied template are checked to ensure that the diagram...

Страница 22: ...DVS Series Installation and Operating Manual 22...

Страница 23: ...Installation and Operating Manual DVS Series 23...

Страница 24: ...HB DVS 3 Baxall Limited Stockport England Visit our Web site http www baxall com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice t...

Отзывы: