5.3 Re-lubrication (optional)
Attention:
Re-lubrication only with grease outlet open.
Prior to re-lubrication it is imperative that the covers be removed from the grease outlet opening.
Re-grease bearing with re-lubrication device only when the motor is running.
After re-lubrication, 2 - 4 hours of motor operation is necessary (the old bearing grease is ejected
from the grease outlet opening by the rotation of the bearing), the cover is then to be refitted to the
grease outlet opening.
The theoretical bearing service life as well as the specified motor protection type can only be
maintained if the grease outlet opening is sealed with the cover supplied during operation.
Re-lubrication intervals and grease quantities can be found on the sign on the motor.
6
Disposal
The motor must be disposed off in accordance with the national and local regulations within the
framework of the normal recycling process.
Attention:
The rotors of the DST motors have rare-earth magnets with high magnetic energy
densities. See also the note in
Section 1.2
.
The encoder electronics (if provided) must be disposed of in the proper manner as electronic
scrap.
Before you open the thrust-bearing motor, the oil for thrust-bearing lubrication must be drained via
the locking screw (
Appendix 3
–
Fig. 8
).
The oil is to be disposed of separately as mineral oil.