Installation
Instruction handbook
Safe STO logic
BM5-SSL
Document No. 5.18007.02
Baumüller Nürnberg GmbH
52
8.3
8.3.3
Connection options
The inputs must be connected according the following connection diagrams.
BM5-SSL000-000
Figure 9:
BM5-SSL-000-000: Potential free contact, p and n switching
Short circuit
Reaction
Cable A
⟺
Cable B
Safety function of
BM5-SSL
is activated.
Cable A
⟺
+24V
Safety function is actuated by one channel only,
BM5-SSL
remains in state STO.
Cable A
⟺
GND
Safety function of
BM5-SSL
is activated.
Cable B
⟺
+24V
Safety function of
BM5-SSL
is activated.
Cable B
⟺
GND
Safety function is actuated by one channel only,
BM5-SSL
remains in state STO.