Commissioning/Operation
Instruction handbook
b maXX
(BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06
47
8
7
Configuration / submenu „IO digital inputs“
Figure 12:
ProDrive navigation, submenu „IO digital inputs“
8
The submenu contains „Digital input link 1 - 4“
e.g. choose „Digital input link 2“.
The window „Digital input link 2“ is opened. The inputs can be selected in the center of
the window.
9
Choose in drop-down menu „Selection input“ the „input
D
.2“ if the
Digital IO module
is used in position
D
.
Figure 13:
Selection „input D.2“