![Baumer VisiLine Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/baumer/visiline/visiline_user-manual_2711018047.webp)
47
9.7.3.2 Sequencer Controlled by Machine Steps (trigger)
A
A
B
B
C
C
Trigger
Sequencer
Start
The figure above shows an example for a half-automated sequencer with three sets of
parameters (A,B and C) from the previous example. The frame counter (z) is set to 2. This
means the camera records two pictures after an incoming trigger signal.
Capability Characteristics of
9.7.4
Baumer-GAPI Sequencer Module
up to 128 sets of parameters
▪
up to 65536 loop passes
▪
up to 65536 repetitions of sets of parameters
▪
up to 65536 images per
▪
trigger event
free running mode without initial
▪
trigger
◄ Figure 41
Example for a half-auto-
mated sequencer.