8.3.4.3 TriggerOverlapped
This signal is active, as long as the sensor is exposed and read out at the same time.
which means the camera is operated overlapped.
Exposure
Readout
t
exposure(n)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
Trigger
Trigger
Overlapped
Once a valid trigger signal occures not within a readout, the "TriggerOverlapped" signal
changes to state low.
8.3.4.4 ReadoutActive
While the sensor is read out, the camera signals this by means of "ReadoutActive".
Exposure
Readout
t
exposure(n)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
Trigger
Readout
Active