![Baumer VisiLine Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/baumer/visiline/visiline_user-manual_2711018046.webp)
46
Baumer Optronic
9.7.2
Sequencer in Camera
xml-file
The Baumer Optronic seqencer is described in the category
“BOSequencer”
by the follow-
ing features:
<Category Name="BOSequencer" NameSpace="Custom">
<pFeature>BoSequencerEnable</pFeature>
Enable / Disable
<pFeature>BoSequencerStart</pFeature>
Start / Stop
<pFeature>BoSequencerRunOnce</pFeature>
Run Once / Cycle
<pFeature>BoSequencerFreeRun</pFeature>
Free Running / Trigger
<pFeature>BoSequencerSetSelector</pFeature>
Configure set of parameters
<pFeature>BoSequencerLoops</pFeature>
Number of sequences (m)
<pFeature>BoSequencerSetRepeats</pFeature>
Number of repetitions (n)
<pFeature>BoSequencerFramesPerTrigger</pFeature>
Number of frames per
trigger (z)
<pFeature>BoSequencerExposure</pFeature>
Parameter exposure
<pFeature>BoSequencerGain</pFeature>
Parameter gain
</Category>
Examples
9.7.3
9.7.3.1 Sequencer without Machine Cycle
Sequencer
Start
A
A
B
B
C
C
The figure above shows an example for a fully automated sequencer with three sets of
parameters (A,B and C). Here the repeat counter (n) is set to 5, the loop counter (m) has
a value of 2.
When the sequencer is started, with or without an external event, the camera will record
5 images successively in each case, using the sets of parameters A, B and C (which con-
stitutes a sequence). After that, the sequence is started once again, followed by a stop of
the sequencer - in this case the parameters are maintained
Figure 40 ►
Example for a fully auto-
mated sequencer.
Содержание VisiLine
Страница 1: ...Baumer VisiLine IP User s Guide for Gigabit Ethernet Cameras...
Страница 2: ...2...
Страница 67: ...67...