BA_OADR20.doc
36/40
Baumer
12.06.2017
Frauenfeld, Switzerland
Technical data
OADR 20I6465/S14F
OADR 20I6565/S14F
OADR 20I6475/S14F
OADR 20I6575/S14F
OADR 20I6485/S14F
OADR 20I6585/S14F
Function
Measuring sensor
Technology
Laser Triangulation
Measuring ranges MB
30...130mm
50.....300mm
100...600mm
Resolution typical
0.005...0.06mm
0.01...0.33mm
0.015...0.67mm
Linear deviation (white ceramics)
< ±0.015... ±0.20mm
< ±0.03... ±1.0mm
< ±0.05... ±2.0mm
Light source
Laser diode red, pulsed
Wavelength
Red light 650nm
Laser beam diameter (64xx)
2...1mm
2mm
2mm
Laser beam width (65xx)
3...5mm
4...12mm
5.5...21mm
Laser beam height (65xx)
2...1mm
2.5mm
2.5mm
Color sensitivity typ.
< 2 x the actual resolution
Suppression of mutual
interference
No active suppression
The synchronization input may be used for asynchronous operation
Temperature drift typical
< ±0.03% of MB / °C
< ±0.03% of MB / °C
< ±0.03% of MB / °C
Ambient light immunity
< 40 kLux
< 8 kLux
< 10 kLux
Measuring rate (depending on
object reflectivity)
300....900us
300....900us
300....2800us
Response time
< 2 x measuring rate
Release time
< 4 x measuring rate
Power on indicator
yes, LED green
Alarm
yes, LED red
Voltage supply range +Vs
12 … 28 VDC
Current consumption
< 100 mA, (at +24V ~40mA)
Analog output
4...20mA and 0...10V
Load resistor at I-Out
< (+Vs - 6V) / 0.02A
Load resistor at U-Out
>100k @ +Vs = 12V .
>10k @ +Vs = 15...28V
Alarm output
yes (high signal beyond MB)
Alarm output type
PNP
Alarm output load current
≤ 100 mA
Voltage drop at PNP
alarm output
max: < +Vs -(4.0V) @ 100mA
typ: +Vs -(2.4V) @ 100mA
Short circuit protection (analog I-
Out, analog U-Out, Alarm-Out)
yes
Reverse polarity protection
yes (supply only)
Material of housing
Stainless steel 1.4404
Material of front optics
PMMA
Material of light guide
PMMA
*
1)
and
*
2)
measured on white ceramic sheet
*
3)
the response time depends on the reflectivity of the object
For objects with a reflectivity < 7% (OADM 20x2480/S14C), the response / release time is increased automatically
up to max. 2.8 ms.
*4)
Missed measurements up to 30 cycles will be suppressed. During this time the analog output stays on hold.
*5)
xx% of full scale measuring range / °C
*
6)
maximum sunlight on a white measuring surface
Содержание OADR 20I6 Series
Страница 9: ...BA_OADR20 doc 9 40 Baumer 12 06 2017 Frauenfeld Switzerland...
Страница 21: ...BA_OADR20 doc 21 40 Baumer 12 06 2017 Frauenfeld Switzerland User Manual Laser distance sensor series OADR 20I6...
Страница 37: ...BA_OADR20 doc 37 40 Baumer 12 06 2017 Frauenfeld Switzerland 7 dimension of laser beam measuring range beam...