BA_OADR20.doc
25/40
Baumer
12.06.2017
Frauenfeld, Switzerland
Shiny objects with a constant structure
Especially shiny objects with a constant structure (lathed or scuffed objects, extruded aluminum profiles, etc.)
could have a negative effect on the measuring result.
Objects with color edges in the same direction:
When color edges are orientated in the right direction, the effect to the measuring result will be minor. If the
color edges are in the wrong direction, the effect will depend on the reflectivity of the different colors.
Profile measurement:
For profile measurements, the sensor axes should be perpendicular to the moving direction.