10
6.
Environmental Requirements
6.1 Temperature and Humidity Range for Storage and Operation
*)
Temperature
Storage temperature
-10°C ... +70°C ( +14°F ... +158°F)
Operating temperature*
+5°C ... +50°C (+41°F ... +122°F)
Housing temperature
**)***)
max. +50°C (+122°F)
* If the environmental temperature exceeds the values listed in the table below, the cam
-
era must be cooled. (see Heat Transmission)
Camera Type
Environmental Temperature
Monochrome
HXG20
+49°C(+120.2°F)
HXG20NIR
+49°C(+120.2°F)
HXG40
+46°C(114.8°F)
HXG40NIR
+46°C(114.8°F)
Color
HXG20c
+49°C(+120.2°F)
HXG40c
+46°C(+114.8°F)
Humidity
Storage and Operating Humidity
10% ... 90%
Non-condensing
T
6.2 Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not 50°C (+122°F)
.
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
It is very important to provide adequate dissipation of heat, to ensure that the housing
temperature does not reach or 50°C (+122°F). As there are numerous possibili-
ties for installation, Baumer do not specifiy a specific method for proper heat dissipation,
but suggest the following principles:
operate the cameras only in mounted condition
▪
mounting in combination with forced convection may provide proper heat dissipation
▪
*)
Please refer to the respective data sheet.
**)
Measured at temperature measurement point (T).
***)
Housing temperature is limited by sensor specifications.
Figure 5 ►
Temperature measure-
ment points of Baumer
HXG cameras.
Содержание HXG
Страница 1: ...Baumer HXG Release 2 User s Guide for Dual Gigabit Ethernet Cameras with CMOSIS Sensors...
Страница 2: ...2...