38
Configurable
11.6.1.3
Outputs
With this feature, Baumer offers the possibility of wiring the output connectors to internal
signals, which are controlled on the software side.
Hereby on cameras of the HXG series,
17
signal sources – subdivided into three catego
-
ries – can be applied to the output connectors.
The first category of output signals represents a loop through of signals on the input side,
such as:
Signal Name
Explanation
Line0
Signal of input "Line0" is loopthroughed to this ouput
Line1
Signal of input "Line1" is loopthroughed to this ouput
Line2
Signal of input "Line2" iys loopthroughed to this ouput
Within the second category you will find signals that are created on camera side:
Signal Name
Explanation
FrameActive
The camera processes a Frame consisting of exposure
and readout
TriggerReady
Camera is able to process an incoming trigger signal
TriggerOverlapped
The camera operates in overlapped mode
TriggerSkipped
Camera rejected an incoming trigger signal
ExposureActive
Sensor exposure in progress
TransferActive
Image transfer via hardware interface in progress
ExposureEnlarged
This output marks the period of enlarged exposure time
Beside the 10 signals mentioned above, each output can be wired to a user-defined
signal ("UserOutput0", "UserOutput1", "UserOutput2", "SequencerOut 0...2" or disabled
("OFF").
(Output) Line 3
state high
state low
(Output) Line 4
state high
state low
(Output) Line 5
state high
state low
IO Matrix
state selection
(software side)
signal selection
(software side)
Off
Line0
Line1
Line2
FrameActive
TriggerReady
TriggerOverlapped
TriggerSkipped
ExposureActive
TransferActive
ExposureEnlarged
UserOutput0
UserOutput1
UserOutput2
Timer1Active
Timer2Active
Timer3Active
SequencerOutput0
SequencerOutput1
SequencerOutput2
User defined Signals
nternal Signals
Loopthroughed
Signals
Figure 36 ►
IO matrix of the
Baumer HXG on output
side.