![Baumer HXC13 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/baumer/hxc13/hxc13_user-manual_2711017009.webp)
9
CameraLink
2.2.
®
Interface
CameraLink
®
is designed for digital cameras in machine vision applications. A "Full Cam-
eraLink
®
" interface can transfer up to 80 bits of data at a rate of max. 680 Mbytes/sec.
Serial Interface
2.3.
The communication via the serial interface is incorporated in the "Base CameraLink
®
"
interface.
Pin-Assignment
2.4.
Base CameraLink
®
Full CameraLink
®
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
1
GND
14
GND
1
GND
14
GND
2
X0-
15
X0+
2
Y0-
15
Y0+
3
X1-
16
X1+
3
Y1-
16
Y1+
4
X2-
17
X2+
4
Y2-
17
Y2+
5
XCLK-
18
XCLK+
5
YCLK-
18
YCLK+
6
X3-
19
X3+
6
Y3-
19
Y3+
7
SERTC+
20
SERTC-
7
100 Ω
term.
20
100 Ω
term.
8
SERTFG-
21
8
Z0-
21
Z0+
9
CC1-
22
CC1+
9
Z1-
22
Z1+
10
CC2+
23
CC2-
10
Z2-
23
Z2+
11
CC3-
24
CC3+
11
ZCLK-
24
ZCLK+
12
CC4+
25
CC4-
12
Z3-
25
Z3+
13
GND
26
GND
13
GND
26
GND
Power Supply
Power VCC
8 VDC ... 24 VDC
Power Consumption
5 W
Power Supply
1
2
3
4
5
6
Pin
Signal
Pin
Signal
Pin
Signal
1 (white)
VCC
3 (green)
STRB
5 (grey)
GND
2 (brown)
VCC
4 (yellow)
DGND
1
6 (pink)
GND
1
DGND - digital GND for signal STRB
Notice
Before applying power to the camera we strongly recommend to verify the used pins of
the power connector, the polarity (+/-) of the leads and the supply voltage.
The camera may only be used with a supply voltage according to the camera speci-
fication (8 VDC .. 24 VDC). Connecting a lower or higher supply voltage, AC voltage,
reversal polarity or using wrong pins of the power connector may damage the camera.
If doing so, the warranty will expire immediately.