5
|
Installation
Baumer Hübner
12
Operating Manual
HMG10 & HMG10P EtherNet/IP | V1, T1
5
Installation
NOTICE
Equipment damage due to mechanical shock
Strong vibration may lead to overload by constraining force.
a) Never apply force. If properly assembled, everything fits smoothly together.
b) Use only suitable tools for disassembly (see chapter on disassembly).
NOTICE
Equipment damage by adhering liquids
Sticky liquids may damage sensing unit and ball bearings. Disassembling a device which is
stuck to the axis can lead to destruction.
a) Do not use adhesive liquids to fasten the device.
5.1
Positioning the support plate
1
2
1
Torx screw M4x10 mm, TX20, ISO 14583 2
Torque plate 360°, attachable in any posi-
tion
Tool
n
20 mm
Содержание HUBNER BERLIN PROFI NET microGen HMG10P
Страница 1: ...V1 T1 9 13 2021 11242672 EN US Operating Manual HMG10 HMG10P EtherNet IP Absolute Encoder...
Страница 43: ......
Страница 44: ...www baumer com worldwide...