6
|
Electrical installation
Baumer Hübner
28
Operating Manual
PMG10 & PMG10P CANopen | V1
1
2
3
5
6
4
Ill. 14:
Connecting the supply cable
1
Terminal connector (wire cross-section
≤ 1.5 mm
2
)
Additional incremental output (optional),
speed switch (optional), programming
interface (PMG10P only)
2
Torx / slotted screw M4x32 mm
3
Terminal box cover
4
Cable shield
5
Cable gland M20x1.5 mm (for cable di-
ameter 5-13 mm)
6
Supply cables (cable diameter 5-13
mm)
Tools
n
t20
n
22 mm
Instruction:
a) Loosen the screws at the terminal box.
b) Lift the terminal box off the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the supply cables into the cable gland, let stick out approx. 50 mm of cable.
e) Assign the supply cables to the terminals.
f) Attach the cable gland to the terminal box.
g) Mount the terminal box at the encoder. For doing so, tighten the screws with a torque of 2-3
Nm.