Tools
n
2.5 mm
Instruction:
a) Attach the coupling onto the encoder shaft according to the related mounting instructions.
b) When using the K 35 spring washer of Baumer Hübner, consider the maximum permitted
tolerances for mounting errors.
c) Fasten the coupling at the specified torque (K 35: Mt = 1 Nm (plastic side), Mt = 1.3 ± 10%
Nm (metal side)). Observe the remarks in the spring washer assembly instructions.
Also see about this
2
Maximum permitted tolerances for mounting errors when using the Baumer Hübner K 35
spring washer [