Baumer Hübner
Electrical installation
|
6
V1 | PMG10 & PMG10P CANopen
Operating Manual
21
1
3
2
4
5
6
7
8
9
Ill. 8:
Connecting the supply cable
1
Torx/slotted head screw M4x32mm
2
CANopen bus terminal box
3
Washer A4 (DIN 137)
4
D-SUB connector
5
Cable shield
6
Connection cable (diameter 5-9 mm)
7
Cable gland M16x1.5 mm (matching ca-
ble diameters 5-9 mm)
8
Terminals
9
D-SUB port (for D-SUB connector)
Tools
n
17 mm
n
T20
Instruction:
a) Loosen the screws at the terminal box.
b) Lift the CANopen® terminal box off the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the connection cables into the cable glands.
e) Assign the supply cables to the terminals.
f) Attach the cable gland to the terminal box.
g) Mount the terminal box at the encoder. For doing so, tighten the screws with a torque of 2-3
Nm.