5
|
Installation
Baumer Hübner
18
Operating Manual
PMG10 & PMG10P CANopen | V1
5.4
Notes when using a claw coupling (e.g. ROTEX®)
NOTICE
Damage to the rotary encoder due to incorrect mounting of the claw coupling.
Blocking of the two coupling halves (coupling claws lie face to face) can damage the rotary en-
coder.
a) Make sure that the coupling claws do not block.
b) Make sure that there is no direct axial stop on the device shaft.
Instruction:
w
Observe the distances L and L1 when mounting the claw coupling.
These distances apply to the device with EURO flange B10 with a depth caliper.
Instruction:
w
When mounting with housing foot B3, keep the distance L1.
L
+
L1
L
L1
1...2 mm
Ill. 7:
Correct assembly of a claw coupling