7.4.10. Parameter 979: Sensor format
Read:
Parameter „Sensor Format“ is to read out the user configuration. „Determinable Revolutions“
(configured number of revolutions) and
„Sensor Resolution“ (configured singleturn resolution) are generally
applied, any other information relates to PROFIdrive telegrams 81 to 83.
Parameter 979
Type Read-only
Data type UINT32 (0x07)
Value range: n/a
Data: 979[0] 0x00005111
Header Info
979[1] 0x80000000
1
st
Sensor(G1) Type (**)
979[2] 0x00002000
Sensor Resolution (*)
979[3] 0x00000000
Shift Factor for G1_XIST1
979[4] 0x00000000
Shift Factor for absolute value in G1_XIST2
979[5] 0x00010000
Determinable Revolutions (*)
979[6] 0x00000000
reserved
to
979[10] 0x00000000
reserved
(*) example, depends on basic encoder and user configuration
(**) if 979[2] to 979[5] valid (otherwise 0x00000000)
7.4.11. Parameter 980: Number list of defined parameter
Read:
Parameter 980 is to read out all supported parameters.
Parameter 980
Type Read-only
Data type unsigned int (0x06)
Value range:
Data: 980[0] 0x039A
922
980[1] 0x039D
925
980[2] 0x03C4
964
980[3] 0x03C5
965
980[4] 0x03CE
974
980[5] 0x03CF
975
980[6] 0x03D2
978
980[7] 0x03D3
979
980[8] 0xEE48
61000
980[9] 0xEE49
61001
980[10] 0xEE4A
61002
980[11] 0xEE4B
61003
980[12] 0xEE4C
61004
980[13] 0xFDE8
65000
980[14] 0xFDE9
65001
980[15] 0
End Mark