Baumer
Functions
|
7
V3 | DAB10, DST53, DST76
Operating Manual
47
7.3.5.4
Timing SSCx
With the function
Timing SSCx
you can set the following time-related behavior:
n
Switching on delay (
Response Delays
)
n
Switching off delay (
Release Delays
)
n
Min. pulse duration/pulse duration extension (
Minimal Pulse Duration
)
The individual functions must be activated. Response and release delays can be activated sep-
arately.
Example of response and release delay
n
Response Delay.SSCx Time
:
4 ms
n
Release Delay.SSCx Time
:
5 ms
10
2
4
6
8
ms
ms
12
14
16
18
20
10
2
4
6
8
12
14
16
18
20
SSCx
Input signal
SSCx
Output signal
Resp. delay
Rel. delay
Ill. 15:
Response and release delay
Example of minimal pulse duration
n
Minimal Pulse Duration.SSCx Time
:
4 ms
n
Minimal Pulse Duration.SSCx Mode
:
1
(positive and negative)
10
2
4
6
8
ms
ms
12
14
16
18
20
10
2
4
6
8
12
14
16
18
20
SSCx
Input signal
SSCx
Output signal
Min. pulse
duration
Min. pulse
duration
Min. pulse
duration
Min. pulse
duration
Ill. 16:
Minimal pulse duration