Baumer
Functions
|
7
V3 | DAB10, DST53, DST76
Operating Manual
45
7.3.5.3
SSC Hysteresis
With the function
SSC Hysteresis
you can define how the hysteresis should be set in relation to
the setpoint. The function is relevant for the
Single Point
and
Window
modes:
n
Single Point
: The hysteresis is set either to the left, right, or center of the setpoint.
n
Windows
: The hysteresis is set either outside, inside, or at the center of the respective set-
point.
Example 1: Hysteresis, not inverted
The amplifier electronics are parameterized as follows:
n
Settings.SSC1 Logic
:
Normal
n
Settings.SSCx Mode
:
Single Point
,
Window
n
Settings.SSCx Setpoint 1
:
200 N
n
Settings.SSCx Setpoint 2
:
800 N
n
Hysteresis.SSCx Alignment Mode
:
Left/Outer
,
Center
,
Right/Inner
n
Hysteresis.SSCx Width
:
100 N
Single Point
Window
Left/
Outer
1000
200
400
600
800
SP1
Hyst
N
N
1000
200
400
600
800
SP1
Hyst
SP2
Hyst
Center
1000
200
400
600
800
Hyst
SP1
N
1000
200
400
600
800
Hyst
SP1
SP2
Hyst
N
Right/
Inner
1000
200
400
600
800
Hyst
SP1
N
1000
200
400
600
800
Hyst
SP1
SP2
Hyst
N