7.3.1.3.3 Filter Moving Average for offset and sensitivity teach-in
The filter
Moving Average
is active on the input signal during the offset und sensitivity teach-in
to increase the measurement accuracy. The filter smoothes the signal course by calculating the
average of a specified number of measured values per filter interval. You can select the number
of measured values per filter interval via IO-Link.
IO-Link Parameter: Filter Moving Average (Moving Average Filter)
Parameter designation
Description
Teach-in.Moving Average Filter
Select the number of measured values per filter interval
of the filter
Moving Average
:
n
0
: Disabled
n
1
: 2 measured values/filter interval (0.25 ms)
n
2
: 4 (0.5 ms)
n
3
: 8 (1 ms)
n
4
: 16 (2 ms)
n
5
: 32 (4 ms)
n
6
: 64 (8 ms)
n
7
: 128 (16 ms)
7.3.2
Low-pass filter (IIR filter)
Optionally, you can run the input signal through a low pass filter (
i
nfinite
i
mpulse
r
esponse filter,
IIR filter). The low-pass filter is recommended in the following cases:
n
Increasing the effective resolution by reducing the noise.
n
Bandwidth limitation when the output signal is used for other signal processing that scans
more slowly.
IO-Link Parameter: Low-pass filter (Input Low Pass Filter)
Parameter designation
Description
Input Low Pass Filter.Enable
Enabling/disabling of the low-pass filter:
n
0
: Disabled
n
1
: Enabled
Input Low Pass Filter.Frequency
Select the limit frequency of the low-pass filter:
n
0
: 1 kHz
n
1
: 500 Hz
n
2
: 200 Hz
n
3
: 100 Hz
n
4
: 50 Hz
n
5
: 10 Hz
n
6
: 10 Hz
n
7
: 5 Hz
n
8
: 2 Hz
n
9
: 1 Hz