Baumer
Functions
|
7
V3 | DAB10, DST53, DST76
Operating Manual
33
7.3.1.3.2 Sensitivity teach-in (teach-in sensitivity)
With the sensitivity teach-in the sensitivity is set in such a way that the current input signal (mV/
V) complies with this process value without changing the previously taught-in offset. The sensi-
tivity and the offset register are affected.
Condition:
ð
You carried out an offset teach-in before the sensitivity teach-in. The taught in offset is not
affected by the sensitivity teach-in and serves as the first reference point.
Instruction:
a) Activate the function sensitivity teach-in via the parameter
Teach-in.Sensitivity Enable
.
b) Carry out the sensitivity teach-in.
ü
The parameter
Customer Sensor Adjustment.Nominal Sensitivity
is set in such a way that
the current input signal (mV/V) presents the process value that is specified in the param-
eter
Teach-in.Sensitivity Process Value
. The offset is not altered.
c) Deactivate the function via the parameter
Teach-in.Sensitivity Enable
(thus preventing the
overwriting of the sensitivity).
Example
A strain sensor is mounted on the supporting stand of a press. The strain sensor has the follow-
ing characteristics ex factory:
n
500 µm/m
n
Sensitivity: 1 mV/V
n
Presented process value when there is no press force: 100 µm/m (= 0.2 mV/V)
n
Presented process value with a press force of 50 kN: 300 µm/m (= 1 mV/V)
Prior to the offset and sensitivity teach-in, enter the following parameters via IO-Link:
n
Customer Sensor Adjustment.Process Value Unit
=
kN
(the press force should be mea-
sured)
n
Customer Sensor Adjustment.Nominal Process Value
=
100
(maximum force to be mea-
sured)
n
Teach-in.Offset Process Value
=
0
n
Teach-in.Sensitivity Process Value
=
50 kN
Parameters:
before
Offset teach-in
after
Offset teach-in
after
Sensitivity teach-
in
Process Value Unit
kN
kN
kN
Nominal Process Value
100
100
100
Nominal Sensitivity
1 (factory setting)
1 (factory setting)
1.6
Offset
0 (factory setting)
0.2
0.2
Содержание DAB10
Страница 51: ...Baumer Annex 9 V3 DAB10 DST53 DST76 Operating Manual 51 9 Annex Also see about this 2 Error Handling 52...
Страница 54: ......
Страница 55: ......
Страница 56: ...www baumer com worldwide 45035996355207819...