BUDE_Manual-CANopen_EN.doc
43/55
Baumer Hübner GmbH
23.10.2012/bja
Berlin, Germany
Object 6509
Offset
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
0h
EEPROM
Yes
Description
Calculated from preset (
Object 6003h)
Values
0..current overall measurement range -1
Object 650B
Serial number
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
xyz
EEPROM
Yes
Description
Progressive serial number
Values
0..4294967295 = Is directly linked with the serial number of the end
test (see object 1018h-4h)