BUDE_Manual-CANopen_EN.doc
28/55
Baumer Hübner GmbH
23.10.2012/bja
Berlin, Germany
Subindex
1..8
Data type
Unsigned 32
Access
Read only
Default
0
EEPROM
No
Description
Error or warning occurred, whereby subindex 1 is the ultimate, subindex
2 the penultimate entry etc.
Values
Not yet defined
Object 1005
COB ID SYNC message
Subindex
0
Data type
Unsigned 32
Access
Read write
Default
80h
EEPROM
Yes
Description
Defined COB ID of the synchronization object (SYNC)
Values
Bit 31
not defined
Bit 30
1 = Sensor generates SYNC messages
0 = generates no SYNC message
Bit 29
1 = 29 bit SYNC COB ID (CAN 2.0B)
0 = 28 bit SYNC COB ID (CAN 2.0A)
Bit 28 - 11 Bit 28 - 11 of the 29 bit SYNC COB ID
Bit 10 - 0 Bit 10 - 0 of the SYNC COB ID
Object 1008
Manufacturer Device Name
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
It depends on the basic encoder
EEPROM
No
Description
Device name in ASCII
Values
Data 0 - 3:
"CO13" = 43h 4Fh 31h 33h
13 bit encoder/converter
"CO18" = 43h 4Fh 31h 38h
18 bit encoder/converter
"CO29" = 43h 4Fh 32h 39h
29 bit encoder/converter
Object 1009
Manufacturer hardware version
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
EEPROM
No
Description
Hardware version in ASCII
Values
Data 0..3
31h 2Eh 30h 30h
= "1.00“