Page 14
For technical questions, please call 1-888-866-5797.
Item 59365
Sa
Fety
Opera
ti
O
n
Maintenance
Setup
troubleshooting
problem
possible causes
Likely Solutions
Tool will not start.
1. Battery Pack not properly connected.
2. Battery Pack not properly charged.
3. Battery Pack stopped working.
4. Tool’s thermal reset
breaker tripped (if equipped).
5. Internal damage or wear. (Carbon
brushes or power switch, for example.)
1. Remove Battery Pack, make sure there
are no obstructions, reinsert the Battery
Pack according to its shape (it should
only fit one way), and press firmly until
the Battery Pack locks in place.
2. Make sure Charger is connected and
operating properly. Give enough time
for Battery Pack to recharge properly.
3. Dispose of old Battery Pack
properly or recycle. Replace Battery Pack.
4. Turn off tool and allow to cool.
Press reset button on tool.
5. Have technician service tool.
Tool operates slowly. 1. Excess pressure applied to workpiece.
2. Battery Pack power low.
3. Battery Pack wearing out.
1. Decrease pressure, allow
tool to do the work.
2. Recharge Battery Pack.
3. Dispose of old Battery Pack
properly or recycle. Replace Battery Pack.
Performance
decreases over time.
1. Carbon brushes worn or damaged.
2. Battery Pack wearing out.
1. Have qualified technician replace brushes.
2. Battery Pack capacity will gradually
decrease through use. If symptoms
are severe, recycle old Battery Pack
(or dispose of properly) and replace it.
Excessive noise
or rattling.
Internal damage or wear.
(Carbon brushes or bearings, for example.)
Have technician service tool.
Overheating.
1. Forcing tool to work too fast.
2. Blocked motor housing vents.
1. Allow tool to work at its own rate.
2. Wear ANSI‑approved safety goggles
and NIOSH‑approved dust mask/
respirator while blowing dust out of
motor using compressed air.
Tool does not
grind effectively.
1. Accessory loose.
2. Accessory damaged, worn or
wrong type for the material.
1. Confirm accessory arbor is correct
and Arbor Bolt is tight.
2. Check condition and type of disc accessory.
Use only proper type of disc
accessory in good condition.
Follow all safety precautions whenever diagnosing or servicing
the tool. Disconnect power supply before service.