1.4
Unit Description
The BAUER BF 100 - 6 fill station panel is used in conjunction with an air-storage system or an air-
compressor to recharge air-bottles.
1.5
Specifications - BF 100 - 6
Medium
air
Operating pressure, std.
3,250 psig (224 bar)
Operating pressure, max.
6,000 psig (414 bar)
Ambient temperature range
32 - 105° F (0 - 40° C)
Inlet pressure gauge
0 - 7,500 psig (0 - 517 bar)
Adjustable pressure regulator
2 @ 6,000 psig In, 0 - 5,000 psig Out
2 @ 6,000 psig In, 0 - 400 psig Out
(2 @ 414 bar In, 0 - 345 bar Out)
(2 @ 414 bar In, 0 - 27.6 bar Out)
BFP (Basic Fill Panel) Dimensions
27" H x 30" W x 10 ¾" D
(68.6 cm H x 76.2 cm W x 27.3 cm D)
Figure 1-1
Wall Mounted Fill Panel; BFP-100-6
1. Inlet Air Pressure Gauge
2. Pressure Regulators
3. Regulator Gauges
4. Fill Valves
5. Fill Gauges
1
3
5
3
4
2
2
4
5
4,500 psig
4,000 psig
300 psig
200 psig