MNL-093558
September 30, 2008
Page 16
BAUER
COMPRESSORS
4.2.2
Installation of the Compressor Unit
The floor/site must be capable of supporting the weight of the unit. Secure the compressor unit to the
floor using ½” lag bolts. Position the unit so that it is level. Permissible inclination of the compressor
unit is listed in Paragraph 1.4.
Ensure that the compressor air intake is supplied with fresh air. The intake air must not contain any
exhaust fumes or flammable vapors such as paint solvents, which may cause an internal fire. Make sure
that the intake air is unobstructed and moisture in the intake air is kept to a minimum. It is important
that units draw in clean air. The quality of the incoming air determines the quality of the compressed
air. This is important even for industrial air, as any incoming fumes will also be compressed and will
increase the toxicity to anyone working with the compressed air.
If a remote control is provided, the unit must be equipped with a clearly visible plate warning the possi-
bility of the unit starting. As an additional measure, anyone starting the unit by remote control must
make sure that no one is checking or operating the unit. For this purpose, a second warning plate should
be provided at the remote control unit.
Observe and maintain an ambient temperature range of 43° to 113° F.
The area in which the compressor unit is installed should be well lit and easily accessible to facilitate
servicing and routine maintenance.
4.2.2.1
Space Requirement
A space of 30 to 40 inches should be maintained on all sides, for maintenance access. If a special setup
is required, reference special setup drawings for necessary spacing of the unit.
4.2.2.2
Ventilation
During normal compression, heat is generated by the compressor and by the drive motor/engine. For
air-cooled compressor units, this heat needs to be vented away by sufficient ventilation.
4.2.2.2.1
Outdoor Installation
It is recommended that all gasoline and diesel engine driven compressor units be installed outdoors.
Additionally, electrically driven compressor units may be installed outdoors only if enclosed with
weatherproof enclosure panels.
^ CAUTION ^
The inclination values listed in Paragraph 1.4 are valid only if the oil level of the compressor is level with
but does not exceed the upper mark of the oil dipstick or oil level sight glass
AUTOMATIC COMPRESSOR CONTROL
UNIT MAY START WITHOUT WARNING!
Before carrying out maintenance and repair work, switch off at the main switch
and ensure the unit will not restart.