TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
SOLUTION
Battery Condition
Indicator lights
YELLOW
(
After
battery has been
completely charged).
Battery still has an
unacceptable level of
sulfation.
Battery must stay connected to
charger and remain in Maintenance-
Float mode (
GREEN
blinking indi-
cator) for 72 hours or longer. Then
REBOOT
(see below).
ERROR and CHARGE
LEDs
blink
simultane-
ously
Charger has timed out
before battery has com-
pletely charged.
Reboot unit by unplugging from
A.C. electrical outlet, disconnect
from battery so there will be no
electrical power going to the unit
from either direction, wait 10 sec-
onds, connect to battery first then
plug into A.C. outlet.