background image

BatteryMINDer

® 

   

Models 36271 & 48021

Rev. D-120913 

 

 

Page 16 

P/N VDC36271/48021-MNL

space between them.  Correct polarity and a good connection will be your 
reward. 

6.  Determine the type of battery you wish to charge. When certain 

press the 

Select Battery Type

 button.  The most common is the 

Flooded

 kind, distinguished by removable filler caps (6) or two (2) 

manifold covers (Maintenance-Free) which should not be removed 
unless specifically allowed by the battery manufacturer.  The second 
most popular is the 

Absorbed Glass Mat

 (AGM) sealed-valve 

regulated type. Lastly is the sealed valve regulated 

GEL

  battery.   

Note

: If unsure of your battery type, check with the battery seller, 

manufacturer or our Tech Support before proceeding further. The normal 
(default) setting of your charger is GEL, as this is the lowest voltage output 
and thus the one least likely to cause your battery to be overcharged, 
should you incorrectly select the wrong battery type. However be aware 
that using the wrong setting for a particular type battery can dramatically 
shorten its life and/or cause potentially explosive gas to be emitted from 
the battery.

7.  After selecting both battery type plug the unit’s power cord into a standard 

– grounded 120 Vac electrical outlet. The Power ON LED Indicator will 
light 

GREEN

. If it does not light 

GREEN

 check the outlet to be sure it is 

functioning. In addition, be sure if outlet is controlled by a switch, no one 
will accidentally shut off the power to the outlet. Check for correct polarity 
= (no ERROR 

RED

 LED Indicator). If ERROR Indicator is lit, reverse the 

charger’s output connections to the battery. 

8.  The Charge – Float LED Indicator will light 

GREEN

. The charger will 

now begin charging by first checking the battery to determine its voltage 
and ability to accept a charge. Should the battery not have a normal fully 
discharged voltage (

31.5V [36271]

 / 

42.0V [48021] 

minimum) the unit will 

begin charging in the “Soft-Start” mode to determine if the battery can 
be safely charged. If it cannot, the Power ON – Error LED will flash 

RED

 

and charging will be stopped. Battery should be carefully checked under 
a load by a qualified person before further attempting to charge it. 

9.  Note

: If the battery does not have a minimum no load OCV (Open 

Circuit Voltage) of 

36 Volts

 / 

48 Volts

, the ERROR LED will light 

RED

 

and charger will reject battery. 

10.  No further effort should be made to charge this battery with this charger 

or any charger. Discard this battery, unless it has just been subjected to a 
long period of continuous discharge under a load such as can occur with 

Содержание 48021

Страница 1: ...271 and 48 Volt 48021 Battery Maintainer Desulfators INSTRUCTION MANUAL All Models Include ATS Temperature Sensor installed Ring Terminals with 15A Fuse EZC 01 EZ Connector Mounting Screws Designed to...

Страница 2: ...for long periods of time and the electrolyte solution begins to break down Sulfur in the solution leaches from the electrolyte sticking to the lead plates as converted lead sulfuric crystals Table Of...

Страница 3: ...could result in a risk of fire and electric shock If an extension cord must be used make sure That pins on plug of extension cord are the same number size and shape as those of plug on charger That ex...

Страница 4: ...ONS a Consider having someone close enough by to come to your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eye...

Страница 5: ...ended rates of charge f Determine voltage of battery by referring to car owner s manual and make sure it matches output rating of battery charger 14 CHARGER LOCATION a Locate charger as far away from...

Страница 6: ...le chassis and then remove clip from battery terminal f See operating instructions for length of charge information 17 FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE A SPARK NEAR THE BATTERY MAY C...

Страница 7: ...ure 80 NOTE If your battery is new and you are certain it was not subject to conditions that could have caused sulfation even before you purchased it then you can disregard our recommendations for qua...

Страница 8: ...mperature Compensated Hydrometer Meter or 4 ball type Full Capacity Percentage 1 270 4 Balls floating 100 1 250 3 Balls floating 75 1 190 2 Balls floating 50 1 150 1 Balls floating 25 1 120 0 Balls fl...

Страница 9: ...of the battery 4 If each cell floats three 3 or more balls or 1250 on gauge type your battery can be desulfated reconditioned 5 Always rinse the tester with fresh water after every use Failure to do s...

Страница 10: ...tage reaches full capacity level or no further increase is seen Note OPTIMA brand Yellow Top starter deep cycle batteries have a fully charged resting voltage of 39 3 52 4 OCV Increase above values ac...

Страница 11: ...BatteryMINDer Models 36271 48021 Rev D 120913 Page 11 P N VDC36271 48021 MNL...

Страница 12: ...tach output to battery terminals RED band Positive BLACK band Negative 3 Ambient Temperature Sensor ATS 1 9 comes already installed on the Temperature Sensor input connector 2 Do not detach 4 Plug AC...

Страница 13: ...attery charge status 2 Temperature Sensor input connector 3 Output cord with quick connect plug 4 Battery Type selection button 5 Input power cordset 6 Mounting tabs 7 Ring Terminal cordset with quick...

Страница 14: ...wait 10 seconds LED Status Table LED Status Power Error and Charging Maintaing LEDs POWER ERROR CHARGE FLOAT A C power disconnected battery connected correctly OFF OFF At SoftStart mode Bulk charge m...

Страница 15: ...he Ring Terminal Assembly Note the BatteryMINDer cord must be removed by pulling on the connector plug not the cord Any damage to the connectors or cord will not be covered by the warranty 2 Never use...

Страница 16: ...ord into a standard grounded 120 Vac electrical outlet The Power ON LED Indicator will light GREEN If it does not light GREEN check the outlet to be sure it is functioning In addition be sure if outle...

Страница 17: ...time allowed by charger If you are certain battery is not defective having read and understood completely all of the above concerns and conditions proceed to reboot unit by unplugging from A C electri...

Страница 18: ...48021 MNL 12V _ 12V _ 12V _ _ 6V _ 6V _ 6V _ _ _ _ 6V 6V 6V _ 8V 8V 8V 8V 8V 8V TO CHARGER TO CHARGER 8 VOLT SERIES 6V 6V 6V 6V 6V 6V 6V 6V TO CHARGER TO CHARGER 6 VOLT SERIES 36 Volt 48 Volt Battery...

Страница 19: ...ge and Float Voltages 36V 48V Temperature Charge Float Charge Float 120 F 41 4 38 4 55 2 V 51 2 V 110 F 120 F 41 7 38 7 55 6 V 51 6 V 100 F 110 F 42 0 39 0 56 0 V 52 0 V 90 F 100 F 42 3 39 3 56 4 V 52...

Страница 20: ...d ever be MAINTAINED in sets of 2 or more Test each cell of All filler cap batteries using an accurate temperature compensated hydrometer Test sealed no filler caps batteries using an accurate DIGITAL...

Страница 21: ...ged it should recover its voltage rise above 6 volts suffi ciently to allow charger to begin an attempt to fully recharge it Battery has rested and still cannot be recovered recharged Battery should b...

Страница 22: ...____ _______________________________________________________ _______________________________________________________ _______________________________________________________ TROUBLESHOOTING GUIDE PROBL...

Страница 23: ...___________________________________________ Model BatteryMINDer 36271 or 48021 Serial Number ___________________________ Place of purchase ___________________________ Date of purchase ________________...

Страница 24: ...r Limited Warranty Your BatteryMINDer product is warrantied for FIVE years from date of purchase at retail against defective material or workmanship We make no warranty other than this limited warrant...

Отзывы: