background image

BatteryMINDer

® 

   

Models 128CEC1 & 244CEC1

Rev. A2-010516 

 

 

 

Page 2 

P/N VDC

128

/

244-CEC1

-QSS

A. WARNING: 

RISK OF EXPLOSIVE GASES

WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS.  

BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL 

BATTERY OPERATION.  FOR THIS REASON, IT IS OF UTMOST 

IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS ON (1) BATTERY 

CHARGER, (2) BATTERY AND (3) PRODUCT USING BATTERY EACH 

TIME YOU USE THE CHARGER.  

1. To reduce risk of battery explosion, follow these instructions and those 

published by manufacturer of any equipment you intend to use in vicinity 

of battery.  Review cautionary marking on these products and on engine.

2. To reduce risk of injury, charge only lead acid type rechargeable batteries.  

Other types of batteries may burst causing personal injury and damage.

3. Do not expose charger to rain or snow.  
4. Use of an attachment not recommended or sold by VDC Electronics may 

result in a risk of fire, electric shock, or injury to persons.  

5. To reduce risk of damage to electric plug and cord, pull by plug rather than 

cord when disconnecting charger.  Make sure cord is located so that it 

will not be stepped on, tripped over, or otherwise subjected to damage or 

stress.

6. An extension cord should not be used unless absolutely necessary.  Use 

of improper extension cord could result in a risk of fire and electric shock.  

If an extension cord must be used, make sure: 

a. That pins on plug of extension cord are the same number, size, and shape 

as those of plug on charger; 

b. Not to operate charger with damaged cord or plug – replace the cord or 

plug immediately.

c.  That extension cord is properly wired and in good electrical condition; and
d.  That wire size is large enough for AC ampere rating of charger as specified 

in 

Recommended Minimum AWG Size Table

.

Recommended Minimum AWG size for Extension Cords For Battery 

Chargers

AC input rating, amperes

AWG size of cord

Equal to or

greater than

But less 

than

Length of cord, feet

25

50

100

150

0

2

18

18

18

16

IMPORTANT SAFETY INSTRUCTIONS - 

SAVE THESE INSTRUCTIONS

This manual contains important safety and operating instructions for all 

BatteryMINDer battery chargers unless otherwise specified.

Содержание 128CEC1

Страница 1: ...attery Maintainer Desulfators Quick Start and Safety Manual All Models Include ATS Temperature Sensor installed Ring Terminals with 15A Fuse Insulated Battery Clip cordset with quick connect plug NOT...

Страница 2: ...age to electric plug and cord pull by plug rather than cord when disconnecting charger Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stre...

Страница 3: ...attention immediately 5 NEVER smoke or allow a spark or flame in vicinity of battery or engine 6 Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit...

Страница 4: ...t be mounted in this manner to ensure long term trouble free life including weatherproof integrity Mounting in any other manner or using un mounted parallel to ground except indoors may cause unit to...

Страница 5: ...POS P post of battery 4 Position yourself and free end of cable as far away from battery as possible then connect NEGATIVE BLACK charger clip to free end of cable 5 Do not face battery when making fin...

Страница 6: ...istilled water only to the liquid level indicator found in each cell Before proceeding further you must be thoroughly familiar with the safety and operating instructions 4 Recharge the battery with th...

Страница 7: ...readings Be certain to read and understand all safety related instructions pages 2 to 7 before proceeding further 2 Measure battery s voltage without any load attached If the voltage is less than 12 4...

Страница 8: ...PLT Load Light ON Float Battery 22V 4A 2A 1A Float Battery 24V 4A 2A 1A Float Battery 26V 4A 2A 1A Float Battery 26V 4A 2A 1A For 244CEC1 model please refer to actual unit 128CEC1 Load Light OFF Soft...

Страница 9: ...AC power connected Green Flashing ECO mode BATTERY CONNECTION GREEN RED Green Steady Battery connected correctly Red Steady Battery connected incorrectly BATTERY WEAK AMBER Amber Steady Battery requi...

Страница 10: ...nstant Voltage stage and every 12 hours while in Float Float sometimes called Maintenance is the charger s long term stage The charger can and should be left connected indefinitely This will keep the...

Страница 11: ...ambient temperature sensor which allows it to vary the output voltage as necessary to properly charge your 12V 0 025 V C or 24V 0 050 V C battery Batteries charged at higher temperatures without comp...

Страница 12: ...of purchase ___________________________ RMA ___________________________ Please register your unit on line within 10 days of purchase Due to the ever changing technology associated with this BatteryMI...

Отзывы: