BatteryMINDer
®
Models 128CEC1 & 244CEC1
Rev. A2-010516
Page 8
P/N VDC
128
/
244-CEC1
-QSS
VDC 128CEC1 LABEL
244CEC1
Load Light OFF
Soft-Start
4A Setting
2A
2A Setting
1A
1A Setting
.5A
Constant
Current
4A
2A
1A
Constant
Voltage
28.2 (Gel)
28.8 (Wet, AGM, Sealed)
29.4 (Odyssey, PLT)
Float
(Charge
Complete)
26.1 (Gel)
26.8 (Wet, AGM, Sealed)
27.2 (Odyssey, PLT)
Load Light ON
Float
(Battery < 22V)
4A
2A
1A
Float
(Battery < 24V)
4A
2A
1A
Float
(Battery < 26V)
4A
2A
1A
Float
(Battery < 26V)
4A
2A
1A
For
244CEC1
model,
please
refer to
actual unit
128CEC1
Load Light OFF
Soft-Start
8A Setting
4A
4A Setting
2A
2A Setting
1A
Constant
Current
8A
4A
2A
Constant
Voltage
14.1 (Gel)
14.4 (Wet, AGM, Sealed)
14.7 (Odyssey, PLT)
Float
(Charge
Complete)
13.05 (Gel)
13.4 (Wet, AGM, Sealed)
13.6 (Odyssey, PLT)
Load Light ON
Float
(Battery < 11V)
8A
4A
2A
Float
(Battery < 12V)
8A
4A
2A
Float
(Battery < 13V)
8A
4A
2A
Float
(Battery < 13V)
8A
4A
2A