BatteryMINDer
®
Models 128CEC1 & 244CEC1
Rev. A2-010516
Page 9
P/N VDC
128
/
244-CEC1
-QSS
Quick Start Instructions
Read and thoroughly understand
ALL SAFETY
Instructions, pages
2 - 7 including Preparing to Charge, Charger Location, DC Connection
Precautions, and Qualifying Your Battery BEFORE proceeding further.
1.
Place the Positive (
RED
) clip on the positive battery terminal.
2.
Place the Negative (
Black
) clip on the negative battery terminal.
3.
Select
Amperage
and
Battery Type
by pressing:
4.
Plug in the BatteryMINDer.
5.
Power and Battery Connection light should be
GREEN
. Indicator will
come on showing state of battery charge and present charging stage.
AMP
BATTERY
TYPE
LED INDICATION TABLE
POWER
GREEN
Green Steady
AC power connected
Green Flashing
ECO mode
BATTERY CONNECTION
GREEN
RED
Green Steady
Battery connected correctly
Red Steady
Battery connected incorrectly
BATTERY WEAK
AMBER
Amber Steady
Battery requires soft-start charging or battery voltage is
< 12.5V / 25.0V after analysis stage
LOAD
AMBER
Amber Steady
The output current is up to the maximum rating in Float mode
BAD CELL
RED
Red Flashing
Battery voltage is < 11.5V / 23.0V after analysis stage
TESTING
BLUE
Blue Steady
Analysis stage
DESULFATING
BLUE
Blue Flashing
Desulfating pulses are in process
TEMPERATURE COMPENSATION
GREEN
BLUE
Green Steady
Ambient temperature > 27°C/80°F
Blue Steady
Ambient battery temperature < 21°C/70°F
VOLTAGE LOW
AMBER
REJECTED
RED
Initial qualification of the battery's condition (at the beginning of Soft-Start stage)
Amber Steady
Voltage: 12 Volt: 3 - 10.5V / 24 Volt: 6 - 21V
Red Flashing
Voltage: 12 Volt: < 3V / 24 Volt: < 3V (Low Voltage)