Configuring the Camera
Basler L301kc
4-21
DRAFT
4.2.4.14 Blue Line Gain
4.2.4.15 Blue Line Offset
Purpose:
To set the gain on the blue line or to read the current blue line gain setting. See Section
for details.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x82
1
2
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0x82
0
2
2 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x82
0
2
2 Bytes
Response:
None
Data Format:
Byte 1
Low byte of blue gain setting
Byte 2
High byte of blue gain setting
Data Range:
The blue line gain setting can range from 0x0060 to 0x03FF
which translates to a dB range of 0 dB to 33.6 dB.
Purpose:
To set the offset on the blue line or to read the current blue line offset setting.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x86
1
2
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0x86
0
2
2 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x86
0
2
2 Bytes
Response:
None
Data Format:
Byte 1
Low byte of blue offset setting
Byte 2
High byte of blue offset setting
Data Range:
The blue line offset setting can range from 0x0000 to 0x00FF
(max. 63.75 least significant bits).
Содержание L301kc
Страница 1: ...Basler L301kc USER S MANUAL Document Number DA00051806 Release Date 13 July 2007...
Страница 4: ......
Страница 14: ...Introduction 1 6 Baslert L301kc DRAFT...
Страница 20: ...Camera Interface 2 6 Basler L301kc DRAFT Figure 2 3 Camera Frame Grabber Interface...
Страница 102: ...Configuring the Camera 4 32 Basler L301kc DRAFT...
Страница 104: ...Mechanical Considerations 5 2 Basler L301kc DRAFT Figure 5 1 L301kc Mechanical Dimensions in mm...
Страница 116: ...Troubleshooting 6 10 Basler L301kc DRAFT...
Страница 118: ...Revision History ii Basler L301kc DRAFT...
Страница 120: ...Feedback iv Basler L301kc DRAFT...
Страница 124: ...Index viii Basler L301kc DRAFT...