Physical Interface
AW00123404000
60
Basler ace USB 3.0
5.8
Opto-isolated Output (Pin 4/Line 2)
The camera is equipped with one dedicated opto-isolated output line designated as Line 2. The
output line is accessed via the 6-pin connector on the back of the camera (pin 4, see
Figure 34
).
In addition, the camera has two direct-coupled GPIO lines, Line 3 and Line 4, that can both be used
as output lines. They are described in Section 5.9 on
page 63
.
5.8.1
Electrical Characteristics
The opto-isolated output line has the advantage of being distinctly more robust
against EMI than a GPIO line used as an output. However, when using the opto-
isolated output line, the delays involved are longer than for a GPIO line.
DANGER
Electric Shock Hazard
Risk of Burn or Death.
The power supply used must meet the Safety Extra Low Voltage (SELV) and
Limited Power Source (LPS) requirements.
A suitable power supply is available from Basler. Contact your Basler sales
representative to order a power supply.
WARNING
Fire Hazard
Risk of Burn
The power supply used must meet the Limited Power Source (LPS) requirements.
A suitable power supply is available from Basler. Contact your Basler sales
representative to order a power supply.
Содержание ace acA1920-155
Страница 4: ......
Страница 50: ...Specifications Requirements and Precautions AW00123404000 40 Basler ace USB 3 0...
Страница 56: ...Camera Drivers and Tools for Changing Camera Parameters AW00123404000 46 Basler ace USB 3 0...
Страница 106: ...Physical Interface AW00123404000 96 Basler ace USB 3 0...
Страница 186: ...Image Acquisition Control AW00123404000 176 Basler ace USB 3 0...
Страница 326: ...Index AW00123404000 316 Basler ace USB 3 0...