AW00123404000
Image Acquisition Control
Basler ace USB 3.0
119
6.4.3.2
Exposure Modes
If you are triggering the start of frame acquisition with an externally generated frame start trigger
(ExFSTrig) signal, two exposure modes are available: timed and trigger width.
Timed Exposure Mode
When timed mode is selected, the exposure time for each frame acquisition is determined by the
value of the camera’s Exposure Time parameter. If the camera is set for rising edge triggering, the
exposure time starts when the ExFSTrig signal rises. If the camera is set for falling edge triggering,
the exposure time starts when the ExFSTrig signal falls. Figure 51 illustrates timed exposure with
the camera set for rising edge triggering.
Trigger width exposure mode is
not
available on acA1920-25um/uc,
acA1920-155um/uc, acA2500-14um/uc, acA3800-14um/uc, and
acA4600-10um/uc cameras.
ExFSTrig Signal Period
Exposure
(duration determined by the
Exposure Time parameter)
ExFSTrig Signal
Fig. 51: Timed Exposure with Rising Edge Triggering