Features
AW00123404000
234
Basler ace USB 3.0
Use Case 2 - Sequencer Set Advance Based on Counter 2 End, One Reset
Use case two is illustrated in Figure 89 on
page 238
and assumes that the following sequencer-
related parameter values are set.
Use Case Two in Overview
Use case two demonstrates synchronous triggering and cycling through all the available four
sequencer sets based on the Counter 2 End trigger source. An addition, one reset of the cycling
occurs.
Sequencer set triggering according to path 0 is controlled by an external trigger via GPIO line
Line 3, configured for input.
In this use case, the cycling through the sequencer sets according to path 1 is based on the
Counter 2 End trigger source that in turn, is based on Counter 2 and its Counter Duration setting.
The cycling is synchronous because the counting of Counter 2 is linked to the frame start triggers:
When a sequencer set has Counter 2 End as the trigger source for sequencer set advance, the
related frame start triggers will be counted by Counter 2 and the sequencer set will be applied to
the frame acquisitions. The same sequencer set will be applied to the following frame acquisitions
until the set end of Counter 2 counting is reached. The end of counting is set by the Counter
Duration parameter value applicable to Counter 2. When the end is reached, the counting will
resume with number one for the next frame start trigger and will apply to the next sequencer set.
As the receding series of frame acquisitions, before, the new series of frame acquisitions will be
subject to Counter 2 counting and the Counter Duration parameter value.
Sequencer Set-related Settings
Sequencer
Set 0
Sequencer
Set 1
Sequencer
Set 2
Sequencer
Set 3
Path 0
First sequencer set of path
0**
0**
0**
0**
Next sequencer set after current one
0**
0**
0**
0**
Trigger source
Line 3 (GPIO)
Line 3 (GPIO)* Line 3 (GPIO)* Line 3 (GPIO)*
Trigger activation
Level High**
Level High**
Level High**
Level High**
Path 1
First sequencer set of path
0**
0**
0**
0**
Next sequencer set after current one
1**
2**
3**
0
Trigger source
Counter 2 End
Counter 2
End*
Counter 2
End*
Counter 2
End*
Counter Duration
1
1
2
1
Trigger activation
Level High**
Level High**
Level High**
Level High**
Table 42: Settings for Sequencer Operation According to Use Case 2.
* Only one trigger source for a path allowed.
**Applies Always, Not Only in this Example
Содержание ace acA1920-155
Страница 4: ......
Страница 50: ...Specifications Requirements and Precautions AW00123404000 40 Basler ace USB 3 0...
Страница 56: ...Camera Drivers and Tools for Changing Camera Parameters AW00123404000 46 Basler ace USB 3 0...
Страница 106: ...Physical Interface AW00123404000 96 Basler ace USB 3 0...
Страница 186: ...Image Acquisition Control AW00123404000 176 Basler ace USB 3 0...
Страница 326: ...Index AW00123404000 316 Basler ace USB 3 0...