Installation Instructions
28 / 86
117900
EN
appliance correctly to the 5-pin plug. If the appliance is installed in countries with
a different power supply, the cable cross-section will increase accordingly and
the cable will need to be replaced.
• The appliance must be earthed in accordance with the safety regulations for
electrical equipment.
• Potential equalisation is carried out at the screw marked
, which is located
under the cable gland for the electrical connection at the rear of the appliance.
• A separate 5-core cable must be provided for the appliance from the 5-pin
socket in the wall to the facility's control cabinet, and its cross-section must
correspond to the maximum electrical power of the appliance with adequate
protection provided by an automatic circuit breaker.
5.3
Water Connection
1. Make sure that the potable water connection is located close to the appliance.
2. Prior to establishing the water connection, flush the tube with enough water to
remove all residues of substances that might be present in the tubes, so that
they do not enter solenoid valves.
3. In order to utilise the water connection, consider the following information:
– The water supply connection is located at the rear of the appliance, to
the left-hand side. The connection to the distribution network valve (A,
Fig. 4) can be made using the supplied flexible pipe or with a ¾"
threaded pipe. The connection must be made in such a way that it
cannot be removed in the event of a pressure overload.
– Before connecting the water supply to the oven, install a pressure
regulator and set it to 2.5
–3.5 bar (50–200 kPa). A filter must be installed
before water is delivered to the oven.
– The on-site water supply must be fitted with a shut-off valve that may be
used to shut off the water supply to the appliance.
– Check the hardness of the water on site or ask your local water supply
company.