Installation and operation
105862
15 / 40
EN
NOTE!
A safe distance between the hob and a cupboard above the hob should be
at least 760 mm.
Fig. 3
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
760
min. 50
min. 20
Air inlet
Air outlet
5 mm
Table 2
3. Make sure that the induction plate is well ventilated and the air inlet and air
outlet are not obstructed.
WARNING!
Accidental touching of the overheated base of the induction plate during
operation may cause burns and unexpected electric shock.
4. Fix a wooden insert in a minimum
distance of 50 mm from the bottom
of the heating plate, using bolts.
Consider for clearances provided in
Fig. 4.
Fig. 4
Содержание IKF 72-2Z