Possible Malfunctions
24 / 32
104609
EN
Malfunction
Alarm
Appliance Condition
Solution
(AL18)
Evaporator low
temperature
Appliance stops
Check water supply
Check the appliance for loss of
the coolant
Check evaporator probe location
(AL19)
Augur motor
thermal alarm 1
Appliance stops
Check thermal wiring of the augur
(CN13 contact)
Check if the motor operates
Check if ice blocks hinder rotation
of the augur and continue
defrosting. If the cooled motor is
still blocked, disassemble the
condenser unit to identify the
cause
(AL20)
Augur motor
thermal alarm 2
Appliance stops
Check thermal wiring of the augur
(CN10 contact)
Check if the motor operates
Check if ice blocks hinder rotation
of the augur and continue
defrosting. If the cooled motor is
still blocked, disassemble the
condenser unit to identify the
cause