Possible Malfunctions
104609
23 / 32
EN
Malfunction
Alarm
Appliance Condition
Solution
(AL11)
Water discharge
pump alarm
Appliance stops and
regularly attempts a
certain number of times
to drain water
Check the water drain tube for
clogging
Check water discharge pump
operation
Check if the level sensor is clean
Check water drain opening of the
drain pan
(AL14)
Condenser
cleaning
Appliance continues
operation
Clean air filter and condenser
(AL15)
Inversion of probes
Appliance stops
Check wiring on the sensor's
PCB; replace the sensor's PCB if
needed
(AL16)
IR probe damaged
Appliance stops
Check probe connection to PCB
Check probe, exchange the
probe. If you check free space in
the storage container first, you
may produce ice for subsequent
30 minutes by touching the
control key.
(AL17)
Evaporator high
temperature
Appliance stops
Check evaporator probe location
and insulation
Check if the appliance is losing
coolant
Check if the condenser is clean
Check if the fan operates
In the case of condensation,
check water supply and water
temperature