Possible Malfunctions
20 / 32
104609
EN
Water Inlet Filter
The water inlet filter must be regularly cleaned, observing the blow indications:
– close the water shut-off valve;
– unscrew water supply tube;
– use tweezers to pull the water inlet filter from the socket at the inlet of the
solenoid valve;
– clean the water inlet filter under running water;
– fit the water inlet filter;
– fit water supply tube.
7
Possible Malfunctions
Mögliche
ATTENTION!
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. These
malfunctions may be cleared by a qualified refrigeration technician.
Malfunction
Alarm
Appliance Condition
Solution
(AL03)
No water alarm (if
a sensor is
equipped)
Appliance stops or waits
for another attempt of
automatic start-up
Check water supply
Check circulation for water leaks
Check water inlet valve for
operation, clean if necessary
Check sensor position
(AL04)
Ice storage
container probe
damage alarm
Appliance stops
Check probe connection to PCB
Check probe integrity