EN
page 50
7.3.2 Electrical connection
The electrical connection shall be carried out in accordance to the local laws in force.
The machine has a connection at the back, indicated by the symbol
, that is meant to link the steel structure and masses
among di
ff
erent apparatuses, to prevent electro-static electrical shocks.
The electrical supply cable must be new,
fl
exible, and according to "har" H07RN-F or a local valid equivalent. The cable size
is dimensioned according to the power.
If the machine is
fi
tted with a three-phase pump, check the correct motor rotation (right rotation as per arrow on the casing).
This is not needed if the pump is a single-phase model (standard).
7.3.3 Water connection
Connect the water in-feed hose, given with the machine, to a ¾” water supply tap.
Connect the machine draining pipe to the connection located at rear, under the back-panel, in such a
way that water
fl
ows freely (therefore ensuring a minimum slope). If the water cannot be discharged
to a level below the machine drain, it is advisable to install a drain pump (supplied on request).
Maximum drain height = cm. 50 (see pic. 9).
The drain tube shall always be connected to a siphon in order to prevent the release of odors.
In those machines equipped with “water softener” the water supply temperature shall not exceed
40°C, to avoid damages to the
fi
lters’ resins.
7.3.4 Start-up
At installation engineer’s care.
7.3 Installation
7.3.1 Positioning the machine
Remove the packing with care.
Lift the machine as described in par.
7.1.1 Handling the product
.
Position the machine as shown on the installation diagram (lay-out) approved at the
time of the o
ff
er.
Maintain a minimum distance of about 50 mm from the walls, so that motors are
ventilated (see pic. 7). Install suction hoods to assure proper ventilation of the room,
in order to eliminate steam and excessive humidity.
Check that the machine is properly levelled, by adjusting the legs (see pic. 8).
Make sure the machine is not standing on the power cable or on the
fi
lling/drain hoses.
Level the machine
fl
at, by adjusting the support feet.
pic. 8
MAX 0,5m
pic. 9
pic. 7
50 mm