- 40 -
Connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid
specification should be compared with that of the device (see
rating plate). Connect the device only in case of compliance!
Before connecting the power supply to the device, the local power grid specification
should be compared with the value of voltage and frequency on the type plate.
Permissible voltage tolerance is ± 10%.
Make sure that there is a power connection with protective conductor available which
is consistent with the applicable regulations. During the connection to the electrical
installation, use the cable with sufficient cross-section.
A multipolar switch must be switched on between the device and the electrical
installation, appropriate for the device’s power. The switch with at least 3 mm
opening must be easily accessible.
Connection to the power supply installation must comply with the applicable
international, national and local regulations.