Installation Instructions
117910
25 / 68
EN
Drain of Condensed Water
WARNING!
The temperature of the steam is very high and can cause scalding on
contact with skin or eyes.
Take special care in the area of the vapour extractor and steam generator!
A sufficient amount of water and steam is released from the cooking cabinet during
the baking process.
Draining the condensed liquid from the condensation hood requires the installation
of an additional rubber hose with a diameter of Ø20 mm, which must also be
connected to the tank.
Excess condensation water from the steam generator is drained through additional
pipes that are connected to the tank.
Condensation water from the tank is drained through the drain hose of the
appliance, which is connected to a heat-resistant hose (Ø50 mm) or a drain pipe in
the building floor.
In both cases, a suitable trap is required.
Connection of Condensation Hood
WARNING!
The electrical connection of the condensation hood may only be made by
authorised personnel.
When installing the condensation hood to the appliance, all safety
regulations for the handling and operation of electrical appliances must be
observed!
• The condensation hood is connected by connecting the hood connection cable
(4 x 0.75 mm2) to the cable gland at the back of the appliance. The connection
cable is connected to the marked terminals in the electrical part of the appliance.
The connection cable is supplied with the condensation hood.
• The connection cable must not come into contact with hot surfaces of the oven.
NOTE!
The condensation hood is not included in the delivery of the oven.