BCS36x8
ex
Series
Connection example
Type 17-A1S4-*HP* and B7-A2S4-****
Subject to technical changes.
05/2020
Page 55 of 78
12.
Supply module Ex i with BCS3608
ex
hand-held scanner
12.1
Connection USB via supply module Ex i - type: 17-A1Z0-0025
(e.g. on Ex-HMI)
12.1.1
Components required
Functional system
BCS3608
ex
-IS
ATEX / IECEx Zone 1/21
NEC / CEC Class I, II, III Division 1
1 x
Wired BCS3608
ex
hand-held scanner
Type:
17-A1S4-1HP0
1 x
Supply module Ex i for hand-held scanners BCS3608
ex
Only available for ATEX / IECEx Zone 1/21
Type: 17-A1Z0-0025
1 x
Connection cable for connection between universal supply module and scanner
Type: 17-A1Z0-0015 or 17-A1Z0-0016 or 17-A1Z0-0017
To be provided by the customer
1 x
1 x USB connection cable to the host PC
Maximum cable length supported: 5 m
Number of cores and recommended cable cross section: see BARTEC User Manual
NB:
– USB only functions as SPP (Serial Port Profile), HID is not supported.
The universal supply module is detected by the host PC as a serial connection (virtual
COM interface)
– Please use standard, shielded data lines to prevent external disturbances.
Recommendation: e.g. use CAT5, similar or higher quality cables
1 x
Ex-HMI with USB 2.0 or USB 3.0 interface
The Ex relevant data of the power supply module Ex i must match the Ex-relevant data of the
Ex-HMI or any other Ex device.
The Ex-relevant data of the BARTEC systems can be found in the corresponding Ex certificates,
user manuals and data sheets. (
www.bartec.com
)
1 x
Terminal program or software keyboard wedge for testing virtual COM communication and data
transmission on the host PC.